Case studies
Real damp investigations, explained
What each client was worried about, what our surveyors actually found, and what they recommended. Real readings from real properties across London and beyond.
What you get in every report
- Independent advice. We never sell treatments.
- Moisture readings, humidity and thermal imaging
- The likely cause, in plain English
- Prioritised recommendations you can act on
Show:
Rotten Stairs and a Spongy Kitchen Floor Found Before Purchase in Lewisham (SE13)
- The problem
- Homebuyer survey flagged rotten boards on the stairs, kitchen and bathroom.
- What we found
- Stair rot went past the first two steps, and the kitchen floor read 100% on the meter.
Pre-purchase damp & timberRead case study →
Damp Wall in a Basement Flat Next to an Under-Pavement Store in Bayswater (W2)
- The problem
- Blown plaster, rotting skirting and a socket pulling off a basement wall.
- What we found
- Below-ground waterproofing failure next to an under-pavement store, not rising damp.
Full damp surveyRead case study →
Fungus Growing Behind Skirting Boards in Richmond (TW9)
- The problem
- Mushrooms growing between the floor and skirting, plus high water bills.
- What we found
- Water meter still moving with everything off: a suspected hidden supply leak.
Thermal imaging & leak detectionRead case study →
Drain Smell in a Fulham Flat That Wouldn’t Go Away After a Leak Was Fixed (W6)
- The problem
- A drain smell in the bedroom stayed after the leak upstairs was fixed.
- What we found
- No active damp. Likely contamination left in the wall, or a drain gas fault.
Thermal imaging damp surveyRead case study →
Basement Water Ingress at a Commercial Building in Clerkenwell (EC1)
- The problem
- Prospective tenants needed to know if a basement would stay dry before signing.
- What we found
- Readings up to 22.1% WME around pavement skylights, plus a costed 6-step repair plan.
Commercial damp surveyRead case study →
Low-Level Damp in a 1950s Semi, and Why a New DPC Wasn’t the Answer (Leicester, LE3)
- The problem
- General survey flagged damp readings on ground-floor walls of a 1950s semi.
- What we found
- DPC intact. Failed pointing and raised decking were the cause. New DPC not justified.
Pre-purchase damp surveyRead case study →
Surveyor Recommended a New Damp-Proof Course on a 1911 House. We Took a Closer Look (Golders Green, NW11)
- The problem
- A surveyor recommended a new damp-proof course for a 1911 house.
- What we found
- DPC bridged by pointing and raised ground, plus an overflow soaking the wall.
Thermal imaging damp surveyRead case study →
A “Free” Survey Said Rising Damp. Here’s What Was Really Going On (Croydon, CR0)
- The problem
- A “free” survey said rising damp, and an earlier treatment had already failed.
- What we found
- Rendered plinth bridging the DPC, blocked drains and a cold bay wall.
Thermal imaging damp surveyRead case study →
Damp Patches That Wouldn’t Dry After a Garage Conversion (Bingham, Nottingham)
- The problem
- Damp patches stayed for over a year after a garage conversion leak was fixed.
- What we found
- Moisture trapped behind dot-and-dab plasterboard on an old solid wall.
Thermal imaging damp surveyRead case study →
Damp Walls After a Timber Floor Was Filled with Concrete (Wandsworth, SW18)
- The problem
- Damp walls appeared after the old timber floor void was filled with concrete.
- What we found
- Floor membrane not sealed into the walls, plus a neighbour’s loose downpipe.
Full damp surveyRead case study →
Flat Roof Leak Still Getting In After a New Asphalt Layer (Shepherd’s Bush, W12)
- The problem
- A roof terrace kept leaking into the salon below, even after a new asphalt layer.
- What we found
- Ponding on the roof, wet layers underneath, and open coping and parapet joints.
Thermal imaging & roof testingRead case study →
Damp in a Kitchen Extension Before Purchase (Stony Stratford, Milton Keynes)
- The problem
- Level 3 survey flagged moisture in a kitchen extension.
- What we found
- Not rising damp. A downpipe, built-up paving and a leaky door threshold.
Pre-purchase damp surveyRead case study →
Trapped Moisture in a 19th-Century House (Aspley Guise, Milton Keynes)
- The problem
- Failing plaster in a 19th-century former butcher’s shop.
- What we found
- Cement finishes trapping moisture, plus render and decking bridging the DPC.
Thermal imaging damp surveyRead case study →
Damp Found Mid-Renovation in a Victorian End-Terrace (Newport Pagnell)
- The problem
- Blown plaster found halfway through a renovation.
- What we found
- Raised paving, blocked vents and a retaining wall. Another DPC not needed.
Full damp surveyRead case study →
Damp and Mould in a Flat Above Shops (Newton Longville, Milton Keynes)
- The problem
- Damp and mould in a flat above shops.
- What we found
- A neighbour’s roof draining into a raised bed against the wall, plus roof defects.
Full damp surveyRead case study →
Mould and Hidden Damp in a Solid-Wall Cottage (Sutton-at-Hone, Dartford)
- The problem
- Mould in a cold solid-wall cottage.
- What we found
- Hidden damp behind dry-looking walls, a bathroom leak and roof defects.
Thermal imaging surveyRead case study →
Leak and Mould Between Two Flats (Dartford, DA1)
- The problem
- A leak from the upper flat caused damp and mould below.
- What we found
- Shower fittings leak, weak extractor (10 l/s vs 15 l/s) and 75% humidity.
Damp & mould surveyRead case study →
Your property
Got a problem like one of these?
Tell us what you’re seeing. A surveyor will get back to you with advice and a quote for the right survey.