Property Rendered solid-wall cottage with later extensions and a conservatory
Location Sutton-at-Hone, Dartford DA2
Survey Thermal imaging survey
Client Homeowner

The problem

The owners of this rendered cottage had mould in the lounge and wanted to understand where moisture was getting in across the house, using thermal imaging to find what couldn’t be seen.

What our surveyor found

  • A hidden leak in the hallway ceiling. Thermal imaging picked out a damp patch, confirmed with a meter, coming from the bathroom above. Condition 3: urgent.
  • Damp at the base of a dining room wall that looked dry. Thermal imaging and readings showed low-level damp along the external walls, where the plinth bridges the damp-proof course and an old bitumen coating has failed.
  • Cracks letting water in at the rear and side, where render had split and separated from the plinth. Readings above DPC level explained the damp in the lounge.
  • A roof defect over bedroom 2: moss, misaligned tiles and gaps, linked to damp found inside.
  • Cold, humid rooms. 72% RH at 14°C in the kitchen (with only a recirculating hood) and 71% RH at 15°C in the dining room. The lounge was cold, with only a single electric heater.
  • Gaps in the conservatory’s decayed timber letting in wind-driven rain above the rear door.
  • Some good news: the gutters were working, a French drain was being installed at the front, and the conservatory DPC was clear and continuous.

Our conclusion

The mould wasn’t one problem. It came from water getting in through render cracks, a bridged DPC and the roof, a live leak from the bathroom, and cold, under-ventilated rooms where moisture condenses.

What we recommended

  1. Fix the bathroom leak first, then dry and repair the hallway ceiling.
  2. Repair the cracked render and the roof over bedroom 2, and remove moss.
  3. Replace the decayed conservatory timbers and seal the junctions.
  4. Deal with the bridged DPC on the affected walls, and consider solid-wall insulation.
  5. Fit a ducted kitchen extractor, add trickle vents and improve the heating.

The takeaway

A wall can look perfectly dry and still be damp inside. Thermal imaging finds these problems early, before plaster fails or timbers start to rot.

We carry out independent damp surveys in Dartford and across north-west Kent.

Got mould or damp you can’t pin down? A thermal imaging survey shows what’s happening behind the surface. Get a free quote.

Related Posts

Basement of a house being damp proofed
Case Study: Basement Water Ingress at a Commercial Building in Clerkenwell (EC1)

Prospective tenants needed to know if a Clerkenwell basement would stay dry before signing a lease. Here is what our survey found and the costed Read more

Case Study: Fungus Growing Behind Skirting Boards in Richmond (TW9)

Mushrooms appeared between the floor and skirting in a Richmond kitchen with underfloor heating. Here is how our survey narrowed down the likely hidden leak.

Case Study: Drain Smell in a Fulham Flat That Wouldn’t Go Away After a Leak Was Fixed (W6)

A tenant in a Fulham flat still had a drain smell in her bedroom after the leak upstairs was repaired. Here is what our surveyor Read more