Property First-floor flat in a building split into several apartments
Location Fulham, London W6
Survey Thermal imaging damp survey
Client Landlord / managing agent

The problem

A tenant had reported a persistent, unpleasant drain smell in her bedroom for some time. A leaking waste pipe in the flat above had been found and repaired. Contractors had been out several times and opened up part of the wall, but found no rodents and no active leak, and the smell was still there. The landlord asked us to check for hidden moisture, leftover water from the old leak, hidden damp or mould, and anything that might explain the smell.

What our surveyor found

  • No significant active damp in the bedroom. Moisture readings and thermal imaging of the accessible walls, floor and skirting did not show water still collecting.
  • The smell was real and drain-related, even though the finishes were dry.
  • High humidity elsewhere in the flat. Readings were around 64% relative humidity on entry, clothes were being dried indoors, and the shower room extractor was switched off. That’s a separate condensation and mould risk, but not the cause of the smell.

Our conclusion: why the smell outlasted the leak

Fixing a leak doesn’t remove what the water left behind. When waste water soaks into plasterboard, insulation or timber inside a wall or floor void, the organic residue can keep smelling for months, even once moisture meters read dry. If the area was closed back up before it was properly cleaned and dried, the smell is sealed in with it.

The other possibility is drain gas escaping from a joint, trap seal or vent pipe serving the flat above. That can happen without any water leaking, so dry readings alone don’t rule it out.

What we recommended

  1. Reopen the enclosure around the repaired pipe and check the joint and the materials around it.
  2. Clean, sanitise and dry anything contaminated, and replace plasterboard or insulation that has soaked up waste water rather than trying to clean it.
  3. Re-test moisture before closing up, and keep trickle vents open while it dries.
  4. No air fresheners. They only hide the problem.
  5. If the smell continues, get a drainage specialist to inspect the pipework above with CCTV, dye or water testing, and check trap seals and drainage ventilation.
  6. Get the shower room extractor running again and cut down indoor clothes drying to bring humidity down.

The takeaway

A lingering smell after a leak is fixed usually means contamination left inside the wall or floor, or a drainage fault that isn’t leaking water. Repainting won’t fix either. Finding which one it is saves repeat call-outs and an unhappy tenant.

Landlord or managing agent dealing with a recurring damp, mould or smell complaint? Our independent damp surveys give you a clear written report you can act on, with findings and recommendations room by room. Get a free quote.

Related Posts

Basement of a house being damp proofed
Case Study: Basement Water Ingress at a Commercial Building in Clerkenwell (EC1)

Prospective tenants needed to know if a Clerkenwell basement would stay dry before signing a lease. Here is what our survey found and the costed Read more

Case Study: Fungus Growing Behind Skirting Boards in Richmond (TW9)

Mushrooms appeared between the floor and skirting in a Richmond kitchen with underfloor heating. Here is how our survey narrowed down the likely hidden leak.

Case Study: Drain Smell in a Fulham Flat That Wouldn’t Go Away After a Leak Was Fixed (W6)

A tenant in a Fulham flat still had a drain smell in her bedroom after the leak upstairs was repaired. Here is what our surveyor Read more