| Property | House with a replacement concrete ground floor and wet underfloor heating |
|---|---|
| Location | Richmond, TW9 |
| Survey | Thermal imaging survey with leak detection checks |
| Client | Homeowner |
The problem
The owners found mushrooms growing out of the gap between the floor and the skirting boards in their open-plan kitchen and dining room, about four weeks before we visited. The ground floor has underfloor heating, which they also used for cooling with their heat pump. They had also noticed their water bills were much higher than expected.
What our surveyor found
- The water meter kept moving with everything switched off. With the washing machine and every other known outlet off, the meter was still turning. That points strongly to water escaping somewhere it shouldn’t.
- The underfloor heating looked less likely. The sealed heating system was holding about 1 bar with no reported pressure loss, and thermal imaging didn’t show the warm patches you’d expect from a leaking heating pipe.
- The stopcock couldn’t be found. Without it we couldn’t isolate the house from the incoming supply, so we couldn’t yet tell whether the leak was inside the house or on the supply pipe outside.
Our conclusion
Fungus at the junction between floor and wall is a warning sign. It needs a steady supply of moisture, and the visible growth only appears long after the water has started collecting. Here the moving meter, the high bills and the fungus together pointed to a suspected concealed leak on the domestic water supply, more than the underfloor heating. Water escaping under a concrete floor can travel along the slab and come out at the skirting, where it finds the timber that fungus feeds on.
We rated this Condition 3: suspected hidden water escape needing priority investigation.
What we recommended
- Find the stopcock and do a controlled meter test. If the meter still moves with the internal stopcock shut, the leak is on the supply pipe between the meter and the house. If it stops, the leak is inside.
- Specialist leak detection before any digging. Acoustic detection, tracer gas or pressure testing to pinpoint the leak. Opening a floor blind risks hitting the underfloor heating pipes.
- Keep monitoring the heating pressure and get a heating engineer to pressure test each circuit if it starts dropping.
- Get monthly usage records from the water supplier to compare against previous years.
The takeaway
If you see fungus or mushrooms at the base of a wall, don’t just clean it off. Check your water meter with everything switched off. It’s a two-minute test that can tell you whether water is escaping before it does more damage.
Got unexplained damp, fungus or rising water bills? Our leak detection and thermal imaging surveys find the source without ripping floors up. Get a free quote.