Property Early-1990s mid-terrace house, cavity walls, ceiling (hydronic) heating, vacant
Location Lewisham, London SE13
Survey Pre-purchase damp and timber survey with thermal imaging
Client Buyer, before exchange

The problem

The buyer’s homebuyer survey found rotten floorboards in three places: around and under the bath, in the kitchen, and on the first two stairs. Before buying, she needed to know how bad it really was. Was it just the boards, or the joists too? Two steps, or the whole staircase? And was it more widespread? She was also worried the ceiling heating system might have slow leaks in more than one place.

What our surveyor found

  • Staircase: worse than first reported. High moisture readings in the stair timbers, deterioration continuing beyond the first two steps, and heavy mould in the cupboard under the stairs.
  • Kitchen: spongy floor. The moisture meter went to the top of its scale (100%), showing a significant moisture problem in the floor or the layers beneath. There was no mechanical extraction in the kitchen.
  • Bathroom: decayed timber between the bath and WC, with readings near the top of the meter’s range, which points to a current or past plumbing leak. The extractor fan had no run-on timer.
  • Blocked air bricks. Both front air bricks and one at the rear were blocked, which can stop the space under the floor being ventilated.
  • Humid air throughout: 67% – 73% relative humidity at 15.8 – 17.8°C, with trickle vents blocked.
  • Elsewhere, broadly fine. No widespread rising or penetrating damp. Thermal imaging didn’t show active leaks in the rooms checked, and old water staining in the airing cupboard was dry. In an empty house, though, an intermittent leak can’t be fully ruled out.

Our conclusion

Overall rating Condition 2 – 3. Most of the house was in acceptable condition, but there were three areas of serious, localised timber decay: the staircase, the kitchen floor and the bathroom. Both plumbing leaks and poor under-floor ventilation (the blocked air bricks) are likely contributors, and the exact causes need confirming by opening up.

What we recommended

  1. Controlled opening-up of the staircase and kitchen floor to check whether joists and supports are affected, not just the boards.
  2. Test the plumbing around the bath, WC and kitchen, with targeted leak detection if needed.
  3. Clear the air bricks and confirm whether there’s a ventilated void under the floor.
  4. Add kitchen extraction, fit a run-on timer in the bathroom and reopen the trickle vents.
  5. Top up loft insulation where gaps were found above the landing.

Why this mattered to the buyer

The homebuyer survey said “rot in three places”. Our report showed the staircase problem was bigger than it looked, put the likely causes on paper, and listed the investigations still needed. That’s the information a buyer needs to renegotiate, ask the seller to fix it first, or walk away.

Has your RICS Level 2 or Level 3 survey recommended a specialist damp or timber inspection? Our pre-purchase damp and timber surveys are independent and written so you can use them in negotiations. Get a free quote.

Related Posts

Basement of a house being damp proofed
Case Study: Basement Water Ingress at a Commercial Building in Clerkenwell (EC1)

Prospective tenants needed to know if a Clerkenwell basement would stay dry before signing a lease. Here is what our survey found and the costed Read more

Case Study: Fungus Growing Behind Skirting Boards in Richmond (TW9)

Mushrooms appeared between the floor and skirting in a Richmond kitchen with underfloor heating. Here is how our survey narrowed down the likely hidden leak.

Case Study: Drain Smell in a Fulham Flat That Wouldn’t Go Away After a Leak Was Fixed (W6)

A tenant in a Fulham flat still had a drain smell in her bedroom after the leak upstairs was repaired. Here is what our surveyor Read more